Product Description:
Shanghai Jingxin Industrial Development Co., Ltd., against the Ministry of Environmental Protection, has developed a new type of tissue grinder JXFSTPRP-YLS (patented product, counterfeiting must be investigated!) ZL2019301918692).
Experimental principle:
Filter a certain amount of sample with a filter membrane to trap the algae, grind and break the algae cells, extract the chlorophyll with acetone solution, measure the absorbance of the extract at 750nm, 664nm, 647nm and 630nm wavelengths after centrifugal separation, and calculate the concentration of chlorophyll a in the water according to the formula.
Application of JXFSTPRP-YLS standard method for extracting chlorophyll:
1. Filtration: Add magnesium carbonate suspension before suction filtration to prevent pigment decomposition. The negative pressure cannot exceed 50kPa.
2. Chlorophyll extraction: place the filter membrane in the JXFSTPRP-YLS extractor, add 10ml of 90% acetone solution, and grind for 1min at 1500-2000rpm. Break the phytoplankton algae cells on the filter membrane. After grinding, it is soaked and extracted in the dark at 4℃, and the soaking time is 2h to 24h. Final centrifugation and clarification: Centrifuge at 1000g for 20 minutes or filter, and transfer the supernatant to a stopcock glass vial.
3. Determination method: spectrophotometry, three-color equation to determine the absorbance of 664nm, 647nm, 630nm, 750nm to calculate the chlorophyll a, b, c chlorophyll content. Determination of the corrected content of pheophytin a by monochromatic equation
JXFSTPRP-YLS can process 18×15 mL centrifuge tubes at the same time for rapid cell disruption, cell lysis, and tissue homogenization.
The ground samples include plant roots, stems, leaves, flowers, fruits, seeds and certain animal tissues; especially suitable for the extraction of nucleic acids, proteins and other components in plant tissues. In addition, it can also break yeast, cultured animal cells, bacterial cells, etc. to extract the components.
The three-dimensional integrated oscillation mode makes the sample grinding more uniform and sufficient, the sample repeatability is good, and there is no cross-contamination between the samples. It is a real high-throughput grinding oscillation system. Each sample only takes 1-2 minutes to complete.
For temperature-sensitive samples, Shanghai Jingxin accessories can be selected for cryogenic grinding and storage.
JXFSTPRP-YLS Applicable samples and applications:
1. PCR (polymerase chain reaction) rapid multi-sample grinding preparation
2. Quickly lyse the tissue homogenate, perform nucleic acid extraction, RNA/DNA extraction, and protein extraction
3. Lysis of yeast and bacterial cells
4. Analysis of pesticides/insecticides (testing food residue pesticides or toxic substances in LC/MS/MS sample processing
5. QuEChERS method (pesticide, antibiotic, drug extraction)
6. Extraction of medicinal active ingredients APIs
7. Food safety (contamination, adulteration, food traceability)
8. Biofuel
Main features of surface water chlorophyll tissue grinder:
? For the application of extracting nucleic acid, protein and its analysis components from plant samples, a specially designed grinding machine is carried out
? High throughput: It can grind 8*15ml samples at the same time, and is suitable for the grinding of samples of various sizes, which greatly improves work efficiency
? Each sample only takes 1-2 minutes to complete
? In order to ensure the reproducibility, effectiveness and comparability of the samples, the grinder can set the grinding time, grinding rate and cycle number to ensure the consistency of each grinding and the next grinding conditions, the maximum time is 99 minutes.
? Built-in two safety locks and a sample compartment cover interlock, extremely safe and reliable.
? Experts in grinding animal and plant samples at room temperature and low temperature
? The start and stop buttons allow the user to start or stop the grinding process at any time.
? Optional Shanghai Jingxin cryogenic accessories for cryogenic grinding and storage of temperature-sensitive RNA and protein extraction samples
technical parameter:
model | JX-PS1 | JX-PS2 | JX-PS3 |
Feed opening size Number of bowls | 120*1 | 130*2 | 130*3 |
Feeding size(mm) | ≤15 | ≤15 | ≤15 |
Discharge size(um) | 10-20 | 10-20 | 10-20 |
Production capacity(g) | 100 | 200 | 300 |
power | 1.1KW (380V) | 1.1KW (380V) | 1.5KW (380V) |
Dimensions(mm) | 480*480*730 | 480*480*730 | 530*530*920 |
Weight | 110 | 115 | 130 |
Grinding tank capacity | 300-3000ml |
|
|
Jar material | Stainless steel, agate, tungsten carbide |