国产精品刺激高潮久久久-亚洲国产精品久久久一区-91精品国产高清片久久久久久-久久久91精品国产一区vip

QuEChERS sample preparation system

Model:JXQE-16A

Brand:Shanghai Jingxin

Specifications :One Set

Introduction:This system is mainly used in the detection of pesticide residues in bees and bee products. The QuEChERS method is used to automatically

QuEChERS sample preparation system JXQE-16A (patented product, counterfeiting must be punished! 201620363493X)

Uses:

This system is mainly used in the detection of pesticide residues in honeybees and bee products. The QuEChERS method is used to automate the extraction and purification processes to extract and purify different samples to complete the pre-processing process.

1. Working conditions:

1.1 Instrument working environment

1.2 Voltage: AC 100-240V

1.3 Room temperature: 5-40℃

1.4. Relative humidity: 20%-90%

Technical parameter:

Main parameters

Parameter range

Parameter range

Overall functional requirements:

The system uses powerful three-dimensional figure-of-eight oscillations to realize the sample extraction function, which can make the sample and the extraction solution more fully function, and the difference between the sample positions is smaller; at the same time, it is organically integrated with the centrifugal function, which can effectively achieve the sample to be tested. Extraction and purification of ingredients.

Oscillation characteristics:

Movement form:

Powerful three-dimensional figure 8 oscillation

 

Oscillation time:

20~999 s

 

Oscillation speed:

4~12m/s

 

Higher speed:

at least 6000 rpm

Sample size:

At least 16 samples can be processed per batch, with a volume of 50ml

Instrument control:

The control system adopts ARM single-chip control

Sample tube sleeve:

Compatible with various specifications of purification tube samples on the market.

Random documents:

The supplier provides detailed operation guides, product manuals, product qualification certificates, maintenance manuals, after-sales service guides, maintenance manuals and quality certifications.

*The instrument has an unbalance monitoring function

*The instrument has over-temperature monitoring and overload monitoring functions

basic configuration:

3.1 1 main machine

3.2 16-bit oscillating horizontal 1 rotor

3.3 Gland 1

3.4 50ml extraction tubes 50

3.5 Constant volume plug 50pcs

3.6 Stirring beads 50 packs

4. Technical information

Detailed operating instructions, related information about instrument maintenance and quality certification

5. Technical service

The seller must install and debug the equipment free of charge at the site provided by the buyer, conduct operation tests until it runs normally, and provide free operation and maintenance training for two instrument operators.

6. Technical service
The seller must install and debug the equipment free of charge at the site provided by the buyer, conduct operation tests until it runs normally, and provide free operation and maintenance training for two instrument operators.
7, quality assurance
1 year free warranty, from the date of confirmation of the acceptance report, the warranty period begins. After the warranty period, the winning bidder will provide lifetime service to ensure the supply of spare parts.
8. Delivery date: within 60 days after signing the contract

typical application:

Typical application one, QUECHERS method of rapid sample pretreatment for pesticide residue inspection:

1. JXQE-16A automatic QuEChERS pre-processing all-in-one machine homogenizes 10g of samples and adds 10ml of acetonitrile;

2. JXQE-16Aautomatic QuEChERS pre-processing all-in-one machine oscillates for 1 min, add 1g of sodium chloride and 4g of magnesium sulfate;

3. The JXQE-16A automatic QuEChERS pre-processing integrated machine oscillates for 1 min and centrifuges at 5000 rpm for 10 min to aliquot 1 ml of the acetonitrile layer and add 250 mg of magnesium sulfate 150 mg PSA powder;

4. The JXQE-16A automatic QuEChERS pre-processing integrated machine oscillates for 1 min, and the supernatant is centrifuged and analyzed by GCMS.

Typical application 2: LC/MS method for extracting OTC drugs in water and sludge cake:

1), sample preparation

Put 3.76mL water, 20uL cetirizine, diphenhydramine and diclofenac, and 140μL acetaminophen into a 50ml centrifuge tube. For the sludge sample experiment, weigh the 2.5k freeze-dried sludge and add the same amount of water and medicine as mentioned above. Add 10mL acetonitrile and add it to the EN extraction tube. After JX-QE16 works with a 50ML adapter for 1 minute, it is centrifuged at 4000rpm for 5 minutes.

To

Dispersive solid phase extraction: Take the supernatant (about 7 mL) and place it in a d-SPE dispersive solid phase extraction package. Use the 15ML adapter for JX-QE16A to work for 1 minute, and then centrifuge at 4000 rpm for 5 minutes. Then the extracted supernatant was transferred to a clean 15mL centrifuge tube and evaporated to dryness with nitrogen. Use 1.875 mL of 50:50 acetonitrile and water to make a sample solution.


Inquiry message
*Name:

*Company/City:
*Phone:
*Contact:
*City:
*Code: